Re: [AMBER] how to combine MD trajectories with two different time steps

From: Carlos Simmerling <carlos.simmerling.gmail.com>
Date: Thu, 14 Jan 2010 13:16:14 -0500

you can vary the stride in each trajin command to give constant time interval.


On Thu, Jan 14, 2010 at 12:59 PM, Jayalakshmi Sridhar <jsridhar.xula.edu> wrote:
>
>   Dear Amber Users,
>   I have set of 15 MD trajectories which I need to combine and analyze. The
>   first 6 .mdcrd and .out files have a time step of 0.2ps to a total of 0.5ns.
>   The next 9 files have a time step of 5 ps to a total of 3.5ns. Will it be
>   possible to combine these trajectories and analyze them together? Thanks for
>   the help.
>   Jaya.
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
>

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Jan 14 2010 - 10:30:02 PST