RE: [AMBER] PCA analysis: the first vector is the movement of whole molecule.

From: Hannes Loeffler <hannes.loeffler.stfc.ac.uk>
Date: Fri, 31 Jul 2009 08:27:54 +0100

Ok, I see that you don't really understand what you are doing.

The '*' mask means ALL atoms. Unless this selection is not just the
molecule(s) you are interested in you are obviously trying to fix the
wrong part of your system. So make sure that you use here the same mask
as in the 'matrix' command.

Why simulation length matters? PCA is a statistical method as you are
calculating the variance-covariance matrix as an _average over time_.
This should make it clear to you that you will need sufficient sampling
before you can rely on your results.

Here are two sample input files for computing the
eigenvectors/eigenmodes and the projection of the eigenvectors onto the
trajectory for a protein with 100 residues. The examples are just meant
to guide you. So adapt it to your problem.

-------------------------- PCA.in ------------------------
rms first :1-100.CA

# PCA analysis
matrix covar name PCA :1-100.CA
analyze matrix PCA vecs 25 out evec.pev
-------------------------- PCA.in ------------------------

-------------------------- proj.in ------------------------
# centering and imaging not necessary if selection is just one molecule
center :1-100 mass origin
image origin center

rms first :1-100.CA

projection :1-100.CA modes evec.pev out proj.ppj beg 1 end 25
-------------------------- proj.in ------------------------


Hope that helps,
Hannes.


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Aug 19 2009 - 19:54:31 PDT