Dear Users,
I looked the out file from all replicas and in one replica there was a problem pasted below. It looks like the chiral constrain I set with the molecular is causing the problem and thus SHAKE fails to change the coordinates. I am again trying a simulation without any restrain let see...
----------------
NSTEP = 20000 TIME(PS) = 40.000 TEMP(K) = 327.42 PRESS = 0.0
Etot = -2148.8682 EKtot = 3357.6998 EPtot = -5506.5680
BOND = 885.1275 ANGLE = 2238.7037 DIHED = 2623.0592
1-4 NB = 850.0974 1-4 EEL = 11564.6743 VDWAALS = -1647.4948
EELEC = -17552.8878 EGB = -4478.0646 RESTRAINT = 10.2171
EAMBER (non-restraint) = -5516.7851
------------------------------------------------------------------------------
NMR restraints: Bond = 0.000 Angle = 0.000 Torsion = 10.217
===============================================================================
vlimit exceeded for step 20072; vmax = 23.7610
vlimit exceeded for step 20073; vmax = 22.6276
vlimit exceeded for step 20074; vmax = 228.1686
Coordinate resetting (SHAKE) cannot be accomplished,
deviation is too large
NITER, NIT, LL, I and J are : 0 0 1193 2374 2375
Note: This is usually a symptom of some deeper
problem with the energetics of the system.
---------------
Thank you guys.
Sunita
--- On Tue, 5/5/09, Sunita Patel <sunita_iitb.yahoo.com> wrote:
From: Sunita Patel <sunita_iitb.yahoo.com>
Subject: Re: [AMBER] equilibration stops for dimer simulation with REMD
To: "AMBER Mailing List" <amber.ambermd.org>
Date: Tuesday, May 5, 2009, 10:03 PM
Dear Users,
I didn't get any response of my problem. I checked my dimer equilibration step by doing normal MD at one temperature. It worked fine. Only with replica exchange MD, job aborts after completing few steps as I mentioned in my previous email. However with monomer, REMD does not complain anything.
Could anyone please suggest how can I solve it?
Best regards,
Sunita
Dept of Biochem and Mol Biophys
University of Arizona, AZ
--- On Mon, 5/4/09, Sunita Patel <sunita_iitb.yahoo.com> wrote:
From: Sunita Patel <sunita_iitb.yahoo.com>
Subject: Re: [AMBER] equilibration stops for dimer simulation with REMD
To: "AMBER Mailing List" <amber.ambermd.org>
Date: Monday, May 4, 2009, 7:00 AM
Hi Carlos,
Thanks for your reply.
The equilibration didn't give any error message in the out file. However, the queuing software gave the following output.
--------------------------------------------------------
application called MPI_Abort(MPI_COMM_WORLD, 1) - process 12[cli_12]: aborting job:
application called MPI_Abort(MPI_COMM_WORLD, 1) - process 12
-------------------------------------------------------
The last step of the out file after which equilibration stopped is also given below.
=======================================
NSTEP = 19500 TIME(PS) = 39.000 TEMP(K) = 282.09 PRESS = 0.0
Etot = -3118.8017 EKtot = 2892.7694 EPtot = -6011.5711
BOND = 764.7012 ANGLE = 1948.1010 DIHED = 2561.2296
1-4 NB = 844.0953 1-4 EEL = 11622.4414 VDWAALS = -1680.7828
EELEC = -17555.6673 EGB = -4523.3717 RESTRAINT = 7.6822
EAMBER (non-restraint) = -6019.2533
------------------------------------------------------------------------------
The parameter file for equilibration step is also appended here.
Equilibration
&cntrl
irest=0, ntx=1,
nstlim=100000, dt=0.002,
ntt=3, gamma_ln=1.0,
temp0=281.85, ig=13004,
ntc=2, ntf=2, nscm=1000,
ntb=0, igb=5,
cut=16.0, rgbmax=16.0,
ntpr=500, ntwx=500, ntwr=100000,
nmropt=1,
/
&wt TYPE='END'
/
DISANG=dimer_chir.dat
-------------------------------------------------------------------------
I hope, this information would help you to figure out the problem. I have not done none REMD simulation on this system. As you suggested I will give a try to do normal MD and see.
Thank you so much.
Regards,
Sunita
--- On Sun, 5/3/09, Carlos Simmerling <carlos.simmerling.gmail.com> wrote:
From: Carlos Simmerling <carlos.simmerling.gmail.com>
Subject: Re: [AMBER] equilibration stops for dimer simulation with REMD
To: "AMBER Mailing List" <amber.ambermd.org>
Date: Sunday, May 3, 2009, 4:41 PM
it's not possible to help without more information on "simulation stops". is
there an error message, either in the sander output or output from any
queueing software? does the simulation stop, or keep running but not produce
output? does a non-REMD (normal MD) simulation work fine for the dimer using
exactly the same input but not exchanging?
On Sat, May 2, 2009 at 4:11 PM, Sunita Patel <sunita_iitb.yahoo.com> wrote:
> Dear Users,
>
> I am trying to simulate a dimer using implicit solvent model
> (generalized-Born solvation model) with replica exchange molecular dynamics
> at 16 different replicas. I am using AMBER10. The total number of atoms of
> the system are 4135. I set up the system for 200 ps equilibration at
> different replica temperatures after the minimization. The equilibration
> stops after completing 40ps. However, for the monomer of the same protein,
> it works fine without any problem.
>
> Could anyboby suggest what would be the problem ? When I saw the 40ps
> equilibration trajectory in VMD I didn't see anything wrong in the
> structure. The dimer structure is intact.
>
> Your suggestion will be highly appreciated.
> Thanks.
> -Sunita
>
>
>
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed May 20 2009 - 14:45:18 PDT