Re: [AMBER] test charge

From: Dan Kaps <dan.kaps.yahoo.com>
Date: Fri, 20 Feb 2009 08:58:17 -0800 (PST)

the input file is attached. ________________________________ From: David A. Case <case.biomaps.rutgers.edu> To: AMBER Mailing List <amber.ambermd.org> Sent: Thursday, February 19, 2009 11:48:29 PM Subject: Re: [AMBER] test charge On Thu, Feb 19, 2009, Dan Kaps wrote: > antechamber -fi .pdb -fo prepin -i file.pdb -o file.prepin -at gaff -pf y -j 0 -c bcc -nc 1 > (i don't quite understand why -nc is one but thats the only way it runs > at all) Sorry for not being completely amber-literate, I am actually > a physicist using this for an apparently unorthodox application.  I > also tried using an water molecule as well; however, the water molecule > dissapeared in the .prepin file and was replaced by three "X" with "nan" > as coordinates.  Let me know if there's anything else I left out. As I said before, if you have a "real" closed shell molecule, this is what antechamber is designed for.  It won't handle "test charge" hydrogens, and I'm not sure it will handle multiple molecules (e.g. benzene + water).  It's still not clear what you really want to do, but it sounds like you are trying to make antechamber do something it was not designed to do. If you post the input pdb file, someone on the list might be able to say more. ...dac _______________________________________________ AMBER mailing list AMBER.ambermd.org http://lists.ambermd.org/mailman/listinfo/amber

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber

Received on Sun Feb 22 2009 - 01:10:05 PST