Re: AMBER: Simulated Annealing - Start with Poor Structure

From: Carlos Simmerling <carlos.simmerling.gmail.com>
Date: Tue, 22 May 2007 17:08:28 -0400

I start with leap-built extended structures or with high temperature
structures all the time. I don't run annealing but do run REMD on them
and don't really see problems. you do need to watch out for chirality
inversions and peptide bond isomerization, etc.

On 5/22/07, Seth Lilavivat <sethl.gatech.edu> wrote:
>
> Dear Amber Community,
>
> Simulated annealing: many of you have commented that a poor initial
> structure
> can be the cause of many problems. However, I noticed that several papers
> document that they started with extremely irregular random structures by
> performing high temperature MD (as high as 4000K), unrestrained. I am
> following
> this protocol of running a short MD run at high temp to create a random
> starting
> structure. My algorithm is capable of producing a low energy structure
> that
> satisfies all of the restraints but it doesn't always converge. My
> question is
> this: when is it appropriate to start with a structure that you believe
> to be
> close to the final structure and when do you start with a random
> "disordered"
> structure?
>
> Thanks,
> Seth
> -----------------------------------------------------------------------
> The AMBER Mail Reflector
> To post, send mail to amber.scripps.edu
> To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
>

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed May 23 2007 - 06:07:43 PDT