AMBER: temperature artifacts with andersen and GB?

From: David Mobley <dmobley.gmail.com>
Date: Wed, 11 Apr 2007 09:50:17 -0700

All,

I know the manual highly recommends using Langevin for temperature
control when using GB, but I insisted on trying Andersen anyway while
simulating a small molecule. I find that the average temperature (in
vacuum, or in GB solvent) is consistently too low (i.e., average of
250K over 500000 steps, when thermostatting to 300K, with vrand=500).
Looking at the instantaneous temperatures from the energy file, which
I'm writing every hundred steps, I find that immediately after every
randomization, the "temperature" spikes to about 2800K, then wobbles
around somewhere in teh 100-250K range until the next randomization.

I'm now going to Langevin, which seems to be working fine. But I don't
see any reason why the Andersen thermostat should give this behavior,
so it might be worth looking into.

Thanks,
David
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Apr 15 2007 - 06:07:07 PDT