Re: [AMBER] QM/MM using Amber and Gaussian: Discrepancies between the forces from the gaussian output file and the forces reported in the mdfrc file

From: Goetz, Andreas via AMBER <amber.ambermd.org>
Date: Mon, 11 Nov 2024 02:34:42 +0000

Dear Ge Song,

If this is from a QM/MM calculation, then the difference in forces is due to Lennar-Jones interactions.

If you add “debug = 2,” to your &gau namelist, then the QM/MM interface will print the converted energy in kcal/mol and forces in kcal/mol/Angstrom to mdout. This should match with the numbers that you converted manually as it does not contain LJ energy or forces. In a pure QM calculation (no MM atoms) the forces should match with the content of the mdfrc file.

All the best,
Andy

—
Dr. Andreas W. Goetz
Associate Research Scientist
San Diego Supercomputer Center
Tel: +1-858-822-4771
Email: agoetz.sdsc.edu
Web: www.awgoetz.de

On Nov 10, 2024, at 5:57 PM, Ge Song via AMBER <amber.ambermd.org> wrote:

Dear Amber community,

I am running single point QM/MM in Sander with forces being output. The calculation finished normally, and the energy from the gaussian log file and that from the mdout file are consistent according to https://urldefense.com/v3/__http://archive.ambermd.org/201812/0031.html__;!!Mih3wA!ASmoTRVtoWAjX-zZbgwTGW2sjRB29QG5fnInvrtGLFnlteLbQs_Wx-vZ6A4_VqarXn9HFu3i-kN-NA$ . However, when I also checked the forces, I found they are roughly consistent but significant discrepancies exist:

The forces on the first atom in the gaussian log file (old.gau_job.log) is:
      -0.012109279 -0.000859028 -0.003084640
those are in Hartree/Bohr, converting into kcal/mol would be:
      -14.359     -1.019      -3.658

While in my mdfrc file, they are:
      -14.517     -0.793      -3.978

So, they look similar, but I don't think these errors are neglectable.

I have tried both Amber19 and Amber22, and they gave the same results. Here is my input setting of sander:

Production
&cntrl
 imin=5,
 ntx=5,
 irest=1,
 temp0=300.0,
 cut=9999.0,
 ntb=0,
 ntwx=1,
 ntwf=1,
 ioutfm=0,
 ifqnt=1
/
&qmmm
 qmmask=':1-3',
 qm_theory='EXTERN',
 qmcharge=0,
 spin=1,
 qmshake=0,
 qm_ewald=0, qm_pme=0,
/
&gau
num_threads = 16,
mem='16GB',
use_template=1,
/

And the command line I was using:
mpirun -np 4 sander.MPI -O -i qmmm_rerun.in -o qmmm_rerun.out -p ala_amber.top -c amber_heat.ncrst -y amber_md_frame1.nc -frc mdfrc

Ge Song
Personal Academic Website of Ge - Physics of Life<https://urldefense.com/v3/__https://calvinge.github.io/gesong.github.io/__;!!Mih3wA!ASmoTRVtoWAjX-zZbgwTGW2sjRB29QG5fnInvrtGLFnlteLbQs_Wx-vZ6A4_VqarXn9HFu2ohTHtjQ$ >


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
https://urldefense.com/v3/__http://lists.ambermd.org/mailman/listinfo/amber__;!!Mih3wA!ASmoTRVtoWAjX-zZbgwTGW2sjRB29QG5fnInvrtGLFnlteLbQs_Wx-vZ6A4_VqarXn9HFu1cm7SqMA$

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sun Nov 10 2024 - 19:00:02 PST