Re: [AMBER] atom type error in antechamber

From: Shiyu Wang via AMBER <amber.ambermd.org>
Date: Fri, 13 Sep 2024 09:41:32 +0800

We don't have the default parameters for B atom.

Maybe you should compute the charge information (e.g. RESP charge) via
QM method.

After that generate the charged mol2 file by antechamber with -dr n option.

On 9/12/24 17:01, 홍종희 via AMBER wrote:
> Hi all
>
>
>
> My name is Jong hui Hong
>
>
>
> while I'm doing MD simulation of my protein-ligand complex with AMBER
>
>
>
> I got following error in antechamber running
>
>
>
> No Gasteiger parameter for atom (ID: 3, Name: B1, Type: DU)
>
>
>
> It seems that the problem is because atom B is not there in predifiend atom type definition
>
>
>
> Is there any other way to generate this kind of atom type manually?
>
>
>
> Thanks in advance
>
>
>
> Regards
>
>
>
> Jong hui Hong
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Sep 12 2024 - 19:00:02 PDT