Dear colleagues,
I have been trying to parametrize a metal-containing anion using the MCPB protocol. I managed to run it more or less smoothly but checking the Gaussian .log files I keep finding this Warning in the fc and mk calculations:
Warning! S atom 12 may be hypervalent but has no d functions.
Warning! S atom 35 may be hypervalent but has no d functions.
I used the 6-31G(d,p) basis set for the parametrization, and upon seeing this error I tried to use bigger basis sets:
- 6-311G(d,p)
- cc-pVTZ
- 6-311++G(3df, 2p)
But I still get the same warning. Has anyone encountered this kind of Warning and has an idea of how to approach it?
Thanks a lot!
Regards,
Mario