[AMBER] Default ensemble

From: Shuo-Lin Weng via AMBER <amber.ambermd.org>
Date: Fri, 28 Jul 2023 10:42:06 -0500

Dear Amber users,

I didn't set any volume and pressure control when I ran my production run.
What is the default ensemble in this situation?
Here is my prod.in file:
A simulation for common production-level simulations
 &cntrl
    imin=0, ! No minimization
    irest=1, ! This IS a restart of an old MD simulation
    ntx=5, ! So our inpcrd file has velocities

    ! Temperature control
    ntt=3, ! Langevin dynamics
    gamma_ln=1.0, ! Friction coefficient (ps^-1)
    temp0=300.0, ! Target temperature


    ! Potential energy control
    cut=9.0, ! nonbonded cutoff, in Angstroms

    ! MD settings
    nstlim=12500000, ! 50 ns
    dt=0.004, ! time step (ps)

    ! SHAKE
    ntc=2, ! Constrain bonds containing hydrogen
    ntf=2, ! Do not calculate forces of bonds containing hydrogen

    ! Control how often information is printed
    ntpr=25000, ! Print energies every 100000 steps, 100,000*0.002 =
200ps
    ntwx=25000, ! Print coordinates every 100000 steps to the trajectory
    ntwr=25000, ! Print a restart file every 100000 steps (can be less
frequent)
    ntxo=2, ! Write NetCDF format
    ioutfm=1, ! Write NetCDF format (always do this!)

    ! Wrap coordinates when printing them to the same unit cell
    iwrap=1,

    ! Set water atom/residue names for SETTLE recognition
    watnam='SOL', ! Water residues are named WAT
    owtnm='OW', ! Water oxygens are named O
    hwtnm1='HW1'
    hwtnm2='HW2'

 &end
Thanks for any reply!
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Jul 28 2023 - 09:00:02 PDT