Hi Lukas,
I've tried four-point models before but didn't see much benefit. You may have more success.
You do need LJ parameters for the dummy atom and I used the same procedure as for hydrogen atoms in Eqs 21 and 22 of
Luchko T, Gusarov S, Roe DR, Simmerling C, Case DA, Tuszynski J, Kovalenko A (2010) Three-Dimensional Molecular Theory of Solvation Coupled with Molecular Dynamics in Amber. Journal of Chemical Theory and Computation, 6(3):607–624. https://doi.org/10.1021/ct900460m
Here, oxygen is the enclosing atom and the dummy atom takes the place of hydrogen. You will have to construct your own MDL file.
Hope this helps,
TL
Sent with ProtonMail secure email.
------- Original Message -------
On Tuesday, March 22nd, 2022 at 3:32 AM, Grunewald, Lukas <Lukas.Grunewald.uibk.ac.at> wrote:
> Dear Amber Community,
>
> I am currently trying to do 1D-RISM and 3D-RISM calculations with 4-Point water models, but I am struggling with defining the right LJ-parameters for the dummy atom for the 1D-RISM calculation.
>
> Has anyone of you done 1D-RISM calculations with 4-Point water models before? Did you use LJ-parameters for the 4-Point water model TIP4P on the dummy atom? If so, how did you calculate them? I did not find an input file for a 4-Point water model in the AmberTools and wanted to ask if someone could share his mdl-input file.
>
> Thanks for your help,
>
> Lukas
>
> _______________________________________________
>
> AMBER mailing list
>
> AMBER.ambermd.org
>
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Mar 22 2022 - 11:00:03 PDT