[AMBER] RESP doesn't incorporate charge constraint

From: Daniel Konstantinovsky <daniel.konstantinovsky.yale.edu>
Date: Fri, 7 Jan 2022 12:54:42 -0500

Hello Amber!

I am trying to do RESP charge fitting for an alkyl-modified phosphate. My
input file is below. The fitting runs fine, but does not incorporate my
desired charge constraint (the last eight atoms' charges must be equal to
-1.0). I looked at example files and see no meaningful difference, so I am
stuck. Please help!

Best,
Dan
-----------------------------------------------------
My input file:

Resp charges for organic molecule
 &cntrl
 nmol = 1,
 ihfree = 1,
 ioutopt = 1,
 qwt = 0.00050,
 &end
    1.0
Resp charges for organic molecule
   -1 64
    6 0
    8 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    6 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
    1 0
   15 0
    8 0
    8 0
    8 0
    6 0
    1 0
    1 0
    1 0
    8 -1.0
    1 57 1 58 1 59 1 60 1 61 1 62 1
 63 1 64
    1 1.165900
    1 57
    1 -0.776100
    1 58
    1 -0.776100
    1 59
    1 -0.495400
    1 60
_______________________________________________