[AMBER] Identical results from thermodynamics integration runs

From: zz sheng <shengzizhang.gmail.com>
Date: Tue, 1 Jun 2021 11:43:55 -0400

Hi All,

I am running TI and realized that when starting from the same equilibrated structure and identical input parameters , all TI runs output exactly the same energy and dU/dL values for all steps. I wonder whether this is how the algorithm being designed despite the ig=-1.

The parameters for TI MD after equilibration are below:

 &cntrl
  ntx = 5,
  irest = 0,
  ntpr = 50000,
  ntwx = 0,
  ntwr = 100000,
  ntwe = 0,
  
  ntf = 1,
  ntb = 1,
  cut = 9.0,

  nstlim = 1000000,
  nscm = 0,
  t = 0.0,
  dt = 0.001,
  iwrap = 1,
  
  temp0 = 300.0,
  tempi = 300.0,
  ntt = 1,
  tautp = 2.0,

  ntc = 1,
  tol = 0.000001,
 
   icfe = 1,
   ifsc=1,
   clambda = 0.5,
    scalpha = 0.5,
    scbeta = 12.0,
   logdvdl = 0,
   timask1 = ':175',
    
   timask2 = ':236',
   
   scmask1 = ':175 & !.N,C,O,CA,H,HA',
   scmask2 = ':236 & !.N,C,O,CA,H,HA',
 &end