Re: [AMBER] About time-dependent positional restraints

From: Christina Bergonzo <cbergonzo.gmail.com>
Date: Mon, 13 Jul 2020 08:42:04 -0400

Hello,

As far as I know, there is no way to do this within the ntr=1 framework.

What I do (during initial minimization/equilibration of my system for
dynamics) is to run several short simulations (50-100ps length) with
subsequent decreasing positional restraint weights.
I will run minimization with a particular value (5 kcal/mol A^2), then run
dynamics with the same value.
I step down until I reach zero: (5, 4, 3, 2, 1, 0.5, 0/unrestrained/no
ntr=1 flag).

-Christina

On Fri, Jul 10, 2020 at 9:38 PM David Sáez <davidsaez.udec.cl> wrote:

> Dear Amber community, is there a way to slightly turn off positional
> restraints (ntr=1, restraint_wt) on a molecule?
>
> I though a line like
>
> &wt type='REST', istep1=0, istep2=100, value1=1.0, value2=0, &end
>
> could work, but as &wt is related to nmropt=1 I am not sure if it would
> also affect the keyword ntr=1.
>
> Thanks in advance,
>
> David.,
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>


-- 
-----------------------------------------------------------------
Christina Bergonzo
Research Chemist
Biomolecular Measurement Division, MML, NIST
-----------------------------------------------------------------
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Jul 13 2020 - 06:00:05 PDT