Re: [AMBER] DOCKED LIGAND CONFORMATION INTO AMBER MD

From: Elvis Martis <elvis_bcp.elvismartis.in>
Date: Mon, 10 Feb 2020 17:43:14 +0530

The dlg format is not the correct one for adding hydrogens.
I would recommend converting the best conformation from the dlg file to pdb
or mol2 and define bond orders correctly.
Then use this pdb/mol2 in Gaussian.
Best Regards



On Mon, 10 Feb 2020 at 15:54, Sruthi Sudhakar <sruthisudhakarraji.gmail.com>
wrote:

> Respected group members,
>
> I have been trying to run a md simulation using the best docked structure
> of my ligand with nucleic acids. I obtained the docked structure from the
> dlg file in pdb format. But I cannot add the missing hydrogens or generate
> the parameter files for the same.
> I used the gaussian ESP charge calculated ligand conformation for docking
> and when I used the same for running MD, using "combine" command in tleap,
> my MD runs fine and I could generate all the parameters. But the same
> cannot be done for the docked ligand conformation. So should I continue
> with the charge fitted initial conformation of the ligand. If not please
> suggest a way to use the docked ligand conformation for running MD
> simulation(including the addition of hydrogen).
>
> Thanking you in advance.
>
> Sruthi Sudhakar
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>