[AMBER] steered MD question

From: Baker, Joseph <bakerj.tcnj.edu>
Date: Thu, 23 Jan 2020 15:10:50 -0500

Hi all,

I am running some directional pulling simulations of some filament proteins
using the jar=1 option in amber and fxyz=0,0,1 (filament axis aligned with
the z-direction). My igr1 and igr2 selections in the DISANG file define
some center of mass groups that I am pulling between. In my main simulation
input file in the &cntrl block I am also putting a light restraint on the
igr1 atoms (0.5 kcal/mol/A^2) to prevent rotation of the filament in the
long rectangular water box. Things seem to be working well (no system
crashes or anything like that). I am wondering if there are any subtleties
that I should be aware of in terms of analyzing the force vs extension data
in a simulation that uses both steered MD and light positional restraints
on some of the atoms? Thanks for your comments.

Kind regards,
Joe

------