Re: [AMBER] error

From: MYRIAN TORRES RICO <myriam.torres.iiq.csic.es>
Date: Wed, 08 Jan 2020 16:07:38 +0100

Hi all,

I'm trying yours ideas, but I don't know how to do this in my script:

"If not, do this: use cpptraj, with trajin being the trajectory file:
choose the frame you wish to use. Set trajout to write a restart file "

Have I to modify anything in my script?:
.
.
.
srun /gpfs/apps/NVIDIA/K80/AMBER/14/bin/pmemd.MPI -O -i
./min-tar/min_wat.in -p ./leap/smp-193-ptn3rig.top -c
./vcte/smp-193ptn_vcon3.mdcrd -r ./min-tar/smp-193ptn_min_wat.rst -o
./min-tar/smp-193ptn_min_wat.out -inf
./min-tar/smp-193ptn_min_wat.info -e ./min-tar/smp-193ptn_min_wat.enr
  -ref ./vcte/smp-193ptn_vcon3.mdcrd
.
.
.

Have I to launch the job.sh with cpptraj?...

Thanx in advance


Myriam



>
>
> Bill Ross <ross.cgl.ucsf.edu> escribió:
>
>> When minimizing, there are no velocities.
>>
>> Bill
>>
>> On 12/11/19 9:36 AM, James Kress wrote:
>>> Is there any particular reason the restart files do not contain velocities?
>>> It seems to me that a "true restart" would need to have coordinates and
>>> velocities to accurately continue an interrupted run?
>>>
>>> What am I not understanding?
>>>
>>> Jim
>>>
>>> James Kress Ph.D., President
>>> The KressWorksR Institute
>>> An IRS Approved 501 (c)(3) Charitable, Nonprofit Corporation
>>> "ENGINEERING THE CURE" C
>>> (248) 573-5499
>>>
>>> Learn More and Donate At:
>>> Website: http://www.kressworks.org
>>> Facebook: https://www.facebook.com/KressWorks.Institute/
>>>
>>> Confidentiality Notice | This e-mail message, including any attachments, is
>>> for the sole use of the intended recipient(s) and may contain confidential
>>> or proprietary information. Any unauthorized review, use, disclosure or
>>> distribution is prohibited. If you are not the intended recipient,
>>> immediately contact the sender by reply e-mail and destroy all
>>> copies of the
>>> original message.
>>>
>>> -----Original Message-----
>>> From: David A Case <david.case.rutgers.edu>
>>> Sent: Wednesday, December 11, 2019 11:41 AM
>>> To: AMBER Mailing List <amber.ambermd.org>
>>> Subject: Re: [AMBER] error
>>>
>>> On Wed, Dec 11, 2019, MYRIAN TORRES RICO wrote:
>>>> Exactly, I want to run pmemd using final trayectory (.mdcrd) instead
>>>> firsts coordinates (.crd).
>>> You can't do this (directly): trajectory files have lots of coordinates
>>> (frames) in them, whereas a restart file has only one set of coordinates.
>>> pmemd doesn't know how to start from a trajectory file.
>>>
>>> Do you have a "final" restart file (created with the "-r" flag)?
>>> Might that
>>> not be what you want here, as a starting point for the next MD segment?
>>>
>>> If not, do this: use cpptraj, with trajin being the trajectory file:
>>> choose the frame you wish to use. Set trajout to write a restart file.
>>>
>>> Then you can use the restart file you just created. It won't have any
>>> velocities, so you will have to set ntx=1 and tempi to the initial
>>> temperature you want.
>>>
>>> ....hope this helps....dac
>>>
>>>
>>> _______________________________________________
>>> AMBER mailing list
>>> AMBER.ambermd.org
>>> http://lists.ambermd.org/mailman/listinfo/amber
>>>
>>>
>>> _______________________________________________
>>> AMBER mailing list
>>> AMBER.ambermd.org
>>> http://lists.ambermd.org/mailman/listinfo/amber
>>
>> _______________________________________________
>> AMBER mailing list
>> AMBER.ambermd.org
>> http://lists.ambermd.org/mailman/listinfo/amber




_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Jan 08 2020 - 07:30:02 PST