On Mon, Jun 24, 2019, Akinpelu Olayinka wrote:
>After running Partial and Full minimization for my system of a protein
>and a ligand (GDP) complex, the Heating process is giving the following
>error
>
>Coordinate resetting (SHAKE) cannot be accomplished,
>
> deviation is too large
> NITER, NIT, LL, I and J are : 0 1 2173 4302 4334
Look at what the geometry is around atoms 4302 and 4334. Are these part
of the GDP? Is either one a hydrogen?
> Note: This is usually a symptom of some deeper
> problem with the energetics of the system.
This means that you need to find the source of the underlying problem--
the SHAKE error is just a symptom, not a cause.
If you system has hydrogens connected to phosphates (e.g. in a
protonated GDP), and if those hydrogens have a zero vdW radius, that is
a common source of problems. But you will need to do some investigation
to see if you localize the problem some.
....dac
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Jun 24 2019 - 09:00:03 PDT