Hello Akshay,
There is a very nice tool called ACPYPE, written by Alan W Sousa da Silva
and Wim F Vranken [1]. You can download it at
https://github.com/alanwilter/acpype . We have recently ensured that 1-4
scaling is correctly done within this tool, meaning that Glycam06 is now
converted correctly [2] in addition to the other Amber force fields. We did
an extensive study to ensure that the parameters generate molecular
mechanics and MD observables that are essentially the same (i.e. within a
very small error) for a given Amber leap topology file is used in Amber and
when converted and used in Gromacs.
1. SOUSA DA SILVA, A. W. & VRANKEN, W. F. ACPYPE - AnteChamber PYthon
Parser interfacE. BMC Research Notes 2012, 5:367
doi:10.1186/1756-0500-5-367
http://www.biomedcentral.com/1756-0500/5/367
2. Austen Bernardi, Roland Faller, Dirk Reith and Karl N. Kirschner, ACPYPE
update for Nonuniform 1--4 Scale Factors: Conversion of the GLYCAM06 Force
Field from AMBER to GROMACS, SoftwareX, accepted on April 25, 2019.
Bests,
Karl
On Mon, May 6, 2019 at 11:59 AM Akshay Prabhakant <
akshayresearch16.gmail.com> wrote:
> Just like this page <http://ambermd.org/namd/namd_amber.html>, which shows
> conversion of amber-md input-parameter values into equivalent values for
> namd-input file, can anyone suggest me a way of converting amber-md
> input-parameters to gromacs-md input-paramters(using amber forcefield)?
> Thanks in advance.