Re: [AMBER] Calcutaion of the observed acceptance ratio from simulation

From: Daniel Roe <daniel.r.roe.gmail.com>
Date: Fri, 6 Jul 2018 09:23:08 -0400

The exchange acceptance ratio for the run is printed in the 7th column
of the remlog file (as indicated by the column headers in the remlog
file). You can also get exchange acceptance from the 'remlog' analysis
command in cpptraj (works with multiple input remlog files).

Hope this helps,

-Dan

On Fri, Jul 6, 2018 at 9:07 AM, RITUPARNA ROY
<ritup176122023.iitg.ac.in> wrote:
> Hi,
>
>
> How do i calculate the acceptance ratio P_obs from the rem.log file?
>
> The rem.log file from the tutorial is attached.
>
>
> Thanks in advance.
>
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Jul 06 2018 - 06:30:03 PDT