Hello James,
You have this error because of your membrane is not enough equilibrated . In my experience it may take a long time (>100 ns) to have a well equilibrated system if this this latter is constructed with CHARMM-GUI . So you could run a equilibration stage of your system, first in the NPAT ensemble during dozens ns, and switch to anisotropic ensemble (with lipid14) when you think (see the variations of the , x, y and z values vs. time) that you system is stable.
Good luck
Stéphane
________________________________________
De : James Starlight [jmsstarlight.gmail.com]
Envoyé : vendredi 18 août 2017 09:23
À : AMBER Mailing List
Objet : [AMBER] An equilibration of the membrane protein prepared by charmm-gui
Dear Amber Users!
I have followed Amber tutorial of the membrane protein modeling
embedded in Charmm-gui prepared membrane. On the 6ns of the
unrestrained equilibration my systems has been crashed with following
error:
ERROR: Calculation halted. Periodic box dimensions have changed too
much from their initial values.
Your system density has likely changed by a large amount, probably from
starting the simulation from a structure a long way from equilibrium.
Looking on the system I have found that membrane thickness was
increasing along Z direction.
Question: how long equilibration should be for membrane protein
embedded in charmm-gui prepared membrane ? I have checked a charmm-gui
default protocol and found that the proposed equilibration is very
short. Also they introduce a restraints on the lipids during
equilibration. Is it useful approach to make it shorter?
Thanks !
James
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Aug 18 2017 - 04:00:02 PDT