[AMBER] .prmtop file not saved

From: Shafaq Muzammal <Shafaq.Muzammal.nottingham.ac.uk>
Date: Tue, 23 May 2017 12:33:51 +0000

Dear Amber users,


I am using AMBER 14 for Md simulations of amino acids and pure ionic liquids (without water) by generating the resp charges and producing the library files for all all amino acids and ionic liquid ions. The simulations have been successful using single forcefield i.e. GAFF. Now the problem,


I want to add water to my systems( i have done it using packmol), run the simulations again and for water i have to use ff14SB and parameters from some water model(e.g frcmod.ionsjc_tip4pew). But when i use the following input file for tleap to generate the topology and prmtop files i get the error.


Input file:

source leaprc.gaff

source leaprc.ff14SB

loadamberparams frcmod.ionsjc_tip4pew

loadoff ACT.lib (acetate ion lib)

loadoff EMI.lib (EMIM cation lib)

loadoff LYS-scaled.lib (non-standard LYS charged)

loadamberparams emim.frcmod

loadamberparams acetate.frcmod

loadamberparams lys-charged.frcmod

box= loadpdb box-lys.pdb

setbox box centers

saveamberparm box box-lys.prmtop box-lys.inpcrd


generating prmtop and inpcrd file error by leap

Loading PDB file: ./box-lys-WATER.pdb
 (starting new molecule for chain B)
  (starting new molecule for chain C)
 (starting new molecule for chain D)
Created a new atom named: C1 within residue: .R<NLYS 441>
Created a new atom named: N1 within residue: .R<NLYS 441>
Created a new atom named: C2 within residue: .R<NLYS 441>
. . . . . . . . .
. . . . . . . . .
Created a new atom named: H13 within residue: .R<NLYS 441>
Created a new atom named: H14 within residue: .R<NLYS 441>
Created a new atom named: H15 within residue: .R<NLYS 441>
 Added missing heavy atom: .R<NLYS 441>.A<N 1>
  Added missing heavy atom: .R<NLYS 441>.A<CA 5>
  Added missing heavy atom: .R<NLYS 441>.A<CB 7>
  Added missing heavy atom: .R<NLYS 441>.A<C 23>
  Added missing heavy atom: .R<NLYS 441>.A<CG 10>
  Added missing heavy atom: .R<NLYS 441>.A<O 24>
  Added missing heavy atom: .R<NLYS 441>.A<CD 13>
  Added missing heavy atom: .R<NLYS 441>.A<CE 16>
  Added missing heavy atom: .R<NLYS 441>.A<NZ 19>
One sided connection. Residue: LYS missing connect0 atom.
One sided connection. Residue: default_name missing connect1 atom.
Created a new atom named: C1 within residue: .R<CLYS 480>
Created a new atom named: N1 within residue: .R<CLYS 480>
Created a new atom named: H1 within residue: .R<CLYS 480>
. . . . . . . . .
. . . . . . . . .
Created a new atom named: H13 within residue: .R<CLYS 480>
Created a new atom named: H14 within residue: .R<CLYS 480>
Created a new atom named: H15 within residue: .R<CLYS 480>
  Added missing heavy atom: .R<CLYS 480>.A<OXT 23>
  Added missing heavy atom: .R<CLYS 480>.A<C 21>
. . . . . . . . .
. . . . . . . . .

  Added missing heavy atom: .R<CLYS 480>.A<CE 14>
  Added missing heavy atom: .R<CLYS 480>.A<NZ 17>
  total atoms in file: 8880
  Leap added 44 missing atoms according to residue templates:
       19 Heavy
       25 H / lone pairs
  The file contained 47 atoms not in residue templates
Box dimensions: 63.295869 61.074908 64.409618
Checking Unit.
ERROR: The unperturbed charge of the unit: 0.400270 is not integral.
WARNING: The unperturbed charge of the unit: 0.400270 is not zero.
FATAL: Atom .R<NLYS 441>.A<C1 25> does not have a type.
FATAL: Atom .R<NLYS 441>.A<N1 26> does not have a type.
. . . . . . . . .
. . . . . . . . .
FATAL: Atom .R<CLYS 480>.A<H13 46> does not have a type.
FATAL: Atom .R<CLYS 480>.A<H14 47> does not have a type.
FATAL: Atom .R<CLYS 480>.A<H15 48> does not have a type.
Failed to generate parameters
Parameter file was not saved.

leap creates new atoms within 2 out of 40 LYS residues in the pdb file i.e. No.1 (441) LYS and No.40 (480)LYS in the PDB file. Can anybody suggest how it should be dealt with as i dont want leap to read any of my LYS as CLYS or NLYS?

Regards,

Shafaq





This message and any attachment are intended solely for the addressee
and may contain confidential information. If you have received this
message in error, please send it back to me, and immediately delete it.

Please do not use, copy or disclose the information contained in this
message or in any attachment. Any views or opinions expressed by the
author of this email do not necessarily reflect the views of the
University of Nottingham.

This message has been checked for viruses but the contents of an
attachment may still contain software viruses which could damage your
computer system, you are advised to perform your own checks. Email
communications with the University of Nottingham may be monitored as
permitted by UK legislation.

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue May 23 2017 - 06:00:03 PDT