Dear Amber users
I am trying to perform steered molecular dynamics simulation where I want
to change the distance between two atoms (or better if it is COM between a
group of atoms) as well as changing the angle between three atoms (or COM
again). I have used the following input file:

SMD
 &cntrl
  imin = 0, ntx = 5, irest = 1,
  ntpr = 1000, ntwx = 1000, ntwe = 0, ntwprt=0,
  ntc = 2, ntf = 2, iwrap = 1, ioutfm = 1,
  nstlim = 50001, dt =0.002,
  tempi=300.0, temp0 = 300.0, ntt =1, tautp =2.0,
  ntb = 2, ntp = 1, taup = 2.0, pres0 =1.0, cut = 12.0,
  jar=1,
  /
 &wt type='DUMPFREQ', istep1=1, /
 &wt type='END', /
 DISANG=dist.RST
 DUMPAVE=dist_vs_t
 LISTIN=POUT
 LISTOUT=POUT


And my dist.RST file is:

# Change distance between atoms 1496 and 3647 from 32 A to 5.0 A
&rst iat=1496,3647, r2=32., rk2 = 50., r2a=5.0, /

# Change angle between atoms 1496, 3647 and 4199 from 0 to 360 degree
&rst iat=1496,3647,4199, r2=0., rk2 = 50., r2a=360.0, /


However from the output, it seems that only the first distance restraint is
being applied. How can I solve this?

Thanks in advance
Suchetana Gupta