Re: [AMBER] restarting Amber calculations gives abnormal structures

From: Sadegh Faramarzi Ganjabad <safaramarziganjabad.mix.wvu.edu>
Date: Mon, 3 Apr 2017 02:37:09 -0400

Chris,

Yes I used the same 'refc' file for both original and restart simulation.
Actually, there is no option -ref in my submission script. When I was
running the original simulation, it was complaining about not finding
'refc' file for restraints. Then I copied my input coordinate as 'refc' and
put it on the same directory and ran simulations. However, when I try to
visualize 'refc' on VMD it shows an abnormal structure (I don't know why)
but the atom numbers and coordinates are there.

I removed iwrap=1 and now the restart output structure looks normal.

Thanks,
Sadegh
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Apr 03 2017 - 00:00:02 PDT
Custom Search