Re: [AMBER] EPM2 Force field for CO2

From: David Case <david.case.rutgers.edu>
Date: Mon, 6 Feb 2017 11:03:16 -0500

On Sun, Feb 05, 2017, Liyang Zhu wrote:

> Typically the VDW parameters in Amber is as follows:
>
> * angstrom kcal/mol *
> c1 1.9525 0.1596
> *o 1.7101 0.1463*
>
> And get to know that there is a EPM2 model for CO2 used in many papers,
> which is high accurate for density properties. However, the parameters can
> not be used in amber correctly, because there is always a error of sander
> bomb during NTP equilibrium. The parameter of EPM2 is as follows:
>
> * angstrom kcal/mol *
> c1 2.757 0.0558
> *o 3.033 0.1600*

The Amber Rmin parameters in force field files are actually Rmin/2: that is,
they are atomic radii, not diameters. You don't say what you actually did,
but that might be a part of the problem. If the EPM2 number above is
a sigma value(?), then the Rmin value Amber needs is 3.033*(2**1/6)/2
= 1.702, which is close to the GAFF value you cite above.

If this is not the problem, then you would need to give more information: just
saying "sander bomb" doesn't allow those on the list to offer much real help.

....dac


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Feb 06 2017 - 08:30:02 PST