Dear asdda asa,
> Can we compute RESP charges on compound which geometry-optimized on the
> 3-21G* basis set of the Hartree-Fock?
short answer: yes.
long answer:
Atomic charges per se are a quantum chemical construct, there are no
"correct" charges. In MD simulations, atomic charges are used to model
the electrostatic interaction between atoms.
In Amber, these charges are derived following a rather standardized
protocol, e.g. RESP charges from a HF/6-31G(*) electron density of one
or more structures for ff99SB or FF14SB.
(cf F.-Y. Dupradeau's tools
http://q4md-forcefieldtools.org/FyD/ )
However, the choice of the right structure(s) is up to you; often one
would use a QM geometry optimization at the same level as the RESP
charge derivation, but a different approach is also possible. Thus, you
may obtain "reasonable" charges from a 6-31G(*) electron density
computed for your 3-21G* optimized geometry; but if it is
computationally feasible, I'd suggest a re-optimization of your
structure with the larger 6-31G(*) basis set.
Regards,
Anselm
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Nov 10 2016 - 02:30:03 PST