Dear Ray, Dear Amber (PBSA) users,

I noticed that whenever I try the option sasopt=0 (solvent excluded
surface as molecular surfaces in PB calculations) in combination with
eneopt=4 and frcopt=5 for non-linear PB I get a segmentation fault. When
changing to eneopt=1 and frcopt=0, the calculation runs fine.

I went back at the Wang et al paper 2012 where the sasopt=0 option is
described but I could not find any particular hint on why this should be
incompatible with eneopt=4 and frcopt=5 ... But sure, maybe (probably) I
am missing something ....

Is there any explanation for this behavior ?

Thanks for answering

Best wishes
Vlad

-- 