Re: [AMBER] Regarding Parameter file not saved

From: zoran matovic <zmatovic.kg.ac.rs>
Date: Tue, 19 Jul 2016 10:00:24 +0200

Hi,
It seems that You wish to use shortcut instead to carefully read, repeat and
finally apply (your case) Amber tutorial (manual as well) pages. That’s all
what you need. I do not think You have bonded ligand (sunitinib isn't it?).
Just follow advice from Sandra and good luck.

Just in case that You stuck in procedures I can help You with files:
*.prmtop, *.inpcrd, *.pdb - solvated too -, pdb mol2 ...etc (commands list
as well), important for your case. However, before u ask for it I really
advice to do the example from tutorial page:
http://ambermd.org/tutorials/basic/tutorial4b/index.htm, and then let me
know if you meet a problem .

Cheers
Zoran



-----Original Message-----
From: Vishal Nemaysh
Sent: Monday, July 18, 2016 11:31 AM
To: AMBER Mailing List
Subject: Re: [AMBER] Regarding Parameter file not saved

Respected Sir,

plz help me regarding this problem i can't able to short out the same as i
have chacked as you suggested to me, but i can't find out the exect
solution. please kindly help me.

On Sun, Jul 17, 2016 at 11:45 PM, Hai Nguyen <nhai.qn.gmail.com> wrote:

> Hi,
>
> this is a typical error. Can you try to follow those first
>
> http://archive.ambermd.org/201004/0574.html
>
> other topics
>
> https://www.google.com/search?q=WARNING%3A+There+is+a+bond+of+11.055252+angstroms+between%3A&rlz=1C1CHMO_enUS485US485&oq=WARNING%3A+There+is+a+bond+of+11.055252+angstroms+between%3A&aqs=chrome..69i57j69i58&sourceid=chrome&ie=UTF-8#q=WARNING:+There+is+a+bond+of+angstroms+between
> :
>
> Hai
>
> On Sun, Jul 17, 2016 at 1:52 PM, Vishal Nemaysh <
> vishal.bioinfotech.gmail.com> wrote:
>
> > Respected Sir,
> > I have faced the problem when i saved the .prmtop
> > and .inpcrd fileby appling the following command: but it will showed the
> > following error. how can i resolve it. the pdb complex file is attached
> > herewith plz check the same.
> >
> > *> saveamberparm b comp-lig_w_ions.prmtop comp-lig_w_ions.inpcrd*
> > Checking Unit.
> > WARNING: There is a bond of 11.055252 angstroms between:
> > ------- .R<NLEU 1>.A<CD1 12> and .R<UNK 364>.A<C14 12>
> > WARNING: There is a bond of 13.966544 angstroms between:
> > ------- .R<NLEU 1>.A<CG 10> and .R<UNK 364>.A<C16 11>
> > WARNING: There is a bond of 13.213808 angstroms between:
> > ------- .R<ARG 5>.A<C 23> and .R<UNK 364>.A<C23 1>
> > WARNING: There is a bond of 15.593765 angstroms between:
> > ------- .R<ARG 5>.A<CB 5> and .R<UNK 364>.A<C24 3>
> >
> > -- ignoring the warnings.
> >
> > Building topology.
> > Building atom parameters.
> > Building bond parameters.
> > Could not find bond parameter for: 3C - C*
> > Could not find bond parameter for: C - CZ
> > Could not find bond parameter for: C8 - CZ
> > Building angle parameters.
> > Could not find angle parameter: CT - 3C - C*
> > Could not find angle parameter: CT - 3C - C*
> > Could not find angle parameter: CT - CC - C*
> > Could not find angle parameter: HC - 3C - C*
> > Could not find angle parameter: 3C - CT - CC
> > Could not find angle parameter: 3C - C* - C*
> > Could not find angle parameter: 3C - C* - CC
> > Could not find angle parameter: 2C - 3C - C*
> > Could not find angle parameter: O - C - CZ
> > Could not find angle parameter: C - CZ - NT
> > Could not find angle parameter: C8 - C8 - CZ
> > Could not find angle parameter: HC - C8 - CZ
> > Could not find angle parameter: HC - C8 - CZ
> > Could not find angle parameter: C8 - CZ - NT
> > Could not find angle parameter: CX - C8 - CZ
> > Could not find angle parameter: CX - C - CZ
> > Could not find angle parameter: N - C - CZ
> > Building proper torsion parameters.
> > ** No torsion terms for HC-CT-3C-C*
> > ** No torsion terms for HC-CT-3C-C*
> > ** No torsion terms for HC-CT-3C-C*
> > ** No torsion terms for CT-3C-CT-CC
> > ** No torsion terms for CT-3C-C*-C*
> > ** No torsion terms for CT-3C-C*-CC
> > ** No torsion terms for HC-CT-3C-C*
> > ** No torsion terms for HC-CT-3C-C*
> > ** No torsion terms for HC-CT-3C-C*
> > ** No torsion terms for CT-3C-C*-C*
> > ** No torsion terms for CT-3C-C*-CC
> > ** No torsion terms for CT-CC-C*-C
> > ** No torsion terms for CT-CC-C*-C*
> > ** No torsion terms for HC-3C-CT-CC
> > ** No torsion terms for HC-3C-C*-C*
> > ** No torsion terms for HC-3C-C*-CC
> > ** No torsion terms for 3C-C*-C*-C
> > ** No torsion terms for 3C-C*-C*-CC
> > ** No torsion terms for 3C-C*-CC-NA
> > ** No torsion terms for 3C-C*-CC-CZ
> > ** No torsion terms for HC-2C-3C-C*
> > ** No torsion terms for HC-2C-3C-C*
> > ** No torsion terms for 2C-3C-CT-CC
> > ** No torsion terms for 2C-3C-C*-C*
> > ** No torsion terms for 2C-3C-C*-CC
> > ** No torsion terms for CX-2C-3C-C*
> > ** No torsion terms for O-C-CZ-NT
> > ** No torsion terms for C-CZ-NT-CZ
> > ** No torsion terms for C-CZ-NT-CZ
> > ** No torsion terms for C8-C8-CZ-NT
> > ** No torsion terms for HC-C8-CZ-NT
> > ** No torsion terms for HC-C8-CZ-NT
> > ** No torsion terms for C8-CZ-NT-CZ
> > ** No torsion terms for C8-CZ-NT-CZ
> > ** No torsion terms for CX-C8-CZ-NT
> > ** No torsion terms for CX-C-CZ-NT
> > ** No torsion terms for N-C-CZ-NT
> > ** No torsion terms for C*-3C-CT-CC
> > Building improper torsion parameters.
> > old PREP-specified impropers:
> > <UNK 364>: C18 C20 N19 H39
> > <UNK 364>: C15 N19 C18 O28
> > <UNK 364>: C16 C18 C15 C14
> > total 1146 improper torsions applied
> > 3 improper torsions in old prep form
> > Building H-Bond parameters.
> > Incorporating Non-Bonded adjustments.
> > Parameter file was not saved.
> > >
> >
> > thankyou in advance....
> >
> > --
> > Vishal Nemaysh
> > Research Scholar,
> > Neuropharmaceutical Chemistry Group,
> > Dr. B. R. Ambedkar Center for Biomedical Research,
> > University of Delhi, Delhi-110007
> > Email: *vishal.bioinfotech.gmail.com <vishal.bioinfotech.gmail.com>*
> > Phone: 91-11-27662778 Mobile: 91+8447581401, 91+9650736653
> >
> > _______________________________________________
> > AMBER mailing list
> > AMBER.ambermd.org
> > http://lists.ambermd.org/mailman/listinfo/amber
> >
> >
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>



-- 
Vishal Nemaysh
Research Scholar,
Neuropharmaceutical Chemistry Group,
Dr. B. R. Ambedkar Center for Biomedical Research,
University of Delhi, Delhi-110007
Email: *vishal.bioinfotech.gmail.com <vishal.bioinfotech.gmail.com>*
Phone: 91-11-27662778 Mobile: 91+8447581401, 91+9650736653
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber 
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Jul 19 2016 - 01:30:02 PDT
Custom Search