Re: [AMBER] QM/MM Interface

From: Nisler, Collin R. <nisler.1.buckeyemail.osu.edu>
Date: Sat, 21 May 2016 23:00:52 +0000

Hi Stano, thanks very much for the thorough response. I have tried your suggestions, but I'm getting the same response unfortunately. When I try typing

orca orc_job.inp

on the command line (with orc_job.inp being the input file presumably generated by sander) orca runs fine, which is puzzling. If sander runs orca by calling "orca orc_job.inp" then it doesn't make sense this wouldn't work, since it works when doing it "by hand". This is the orc_job.inp file generated:

# ORCA input file for BLYP/SVP simulation
! BLYP SVP
! SlowConv

%basis
 GTOAux = AutoBuild
end

%scf
 MaxIter 400

 DIISMaxEq 15
 directresetfreq 13

end
! ENGRAD
! Angs NoUseSym
%pointcharges "ptchrg.xyz"
*xyzfile -2 1 inpfile.xyz

Again, thanks for your time.

Collin

________________________________________
From: Stanislav Simko <s.simko.uu.nl>
Sent: Saturday, May 21, 2016 2:37:58 AM
To: amber.ambermd.org
Subject: Re: [AMBER] QM/MM Interface

Dear Collin,
I've just been dealing with similar problems and for me there are
several reasons for this:
1) there's already another program installed that is called orca
(screen reader). In this case you just need to do "prepend-path" to
your orca location, i.e. either (for bash):
prepend-path PATH "/path/to/orca"
or smth. like:
export PATH=path/to/orca:$PATH

2) Assume that it's installed in the "/apps/orca_directory" directory.
When running ORCA in parallel you MUST specify whole path to orca
binary file, i.e.:
/apps/orca_directory/orca input > output

however, I think this is not the case for the Amber that runs it just
like "orca" command. Therefore, I suggest you to :

a) create alias for orca command in your .bashrc file, or somewhere
else:
alias orca='/full/path/to/orca_dir/orca'

b) add following lines to your submit script so that the alias gets
interpreted (bash terminal):
. ~/bashrc
shopt -s expand_aliases

3) It may also be that you Orca calculation does not reach the point
where it creates .engrad file. To test for that I suggest you to just
take the .inp + coordinates + charges prepared by the Amber and run it
directly by Orca to find out. It is very probable that you need to add
section:
%BASIS GTOAUX=AutoBuild END

to you orc_job.tpl file

Regards,
stano.





On Sat, 2016-05-21 at 05:37 +0000, Nisler, Collin R. wrote:
> Hello, I am attempting to run a QM/MM simulation with an external
> interface to Orca. I am able to run it on my machine (albeit very,
> very slowly). I get the Orca output files and the SCF converges well.
> However, when I try to run this in parallel (on a supercomputer) I am
> getting the following error:
>
>
> SANDER BOMB in subroutine read_results (qm2_extern_orc_module)
> Error reading Orca output from file orc_job.engrad
> (Current total energy or gradient not found or unsupported units.)
>
> I get a similar response when I try to use qchem with amber. I think
> Amber and Orca are just not able to communicate like they should, but
> I am completely unsure as to why. This happens both when I submit the
> job in a batch script, or on the command line. Any suggestions would
> be greatly appreciated, thanks for your time.
>
> Collin Nisler
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat May 21 2016 - 16:30:04 PDT