Re: [AMBER] Equilibrium temperature is higher than the target temperature in Langevin dynamics

From: jinfeng liu <jinfengliu1119.gmail.com>
Date: Wed, 25 Nov 2015 23:24:16 +0800

My mdin file is:

 product MD
 &cntrl
  imin=0,irest=1,ntx=5,
  nstlim=50000,dt=0.001,
  ntc=1,ntf=1,iwrap=1,
  ntp=1,taup=2.0,
  cut=12.0, ntb=2, igb=0,
  ntpr=1, ntwx=1, ntwr=1,
  ntt=3, gamma_ln=2.0,
  temp0=300.0,
 /

Actually, I was not performing the strict MD simulation. I performed a
QM/MM-like MD simulation, where the water molecules in the QM zone could
exchange with those in the MM zone, by using the combination of Amber and
my own program.

2015-11-25 23:02 GMT+08:00 David A Case <david.case.rutgers.edu>:

> On Wed, Nov 25, 2015, jinfeng liu wrote:
> >
> > Recently, I performed molecular dynamics of the liquid water in TIP3P
> > model. After the system was heated to 300K and equilibrated in 300 ps, I
> > run the producution simulation. The temperature was controlled using the
> > Langevin dynamics (ntt=3, gamma_ln=2.0) durig the production simulation.
> > However, the equilibrium temperature (305K) was slightly higher than the
> > target temperature which was 300K.
>
> Something is wrong here. Can you post your mdin file? I fear that some
> unexpected combination of input parameters is leading to this result.
>
> ....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Nov 25 2015 - 07:30:08 PST