Hi Amber users,
I'm trying to run the following script for the production step of my simulation:
module load amber
cd /work/e280/e280/enxds6/PLP
export MPICH_FAST_MEMCPY=1
export MPI_COL_OPT_ON=1
aprun -n 96 pmemd.MPI -O -i LAMPLP_MD2.in -o LAMPLP_MD1.out -p LAMPLP.prmtop -c LAMPLP_heat2fs.rst -r LAMPLP_MD1.rst -x LAMPLP_MD1.mdcrd -ref LAMPLP.inpcrd
echo "DONE"
but it stops immediately with the message:
ModuleCmd_Load.c(226):ERROR:105: Unable to locate a modulefile for 'null'
ModuleCmd_Load.c(226):ERROR:105: Unable to locate a modulefile for 'null'
At line 463 of file mdin_ctrl_dat.F90 (unit = 5, file = 'LAMPLP_MD2.in')
Fortran runtime error: Cannot match namelist object name restraint_mask
[NID 00124] 2015-09-12 21:41:19 Apid 17488296: initiated application termination
Application 17488296 exit codes: 2
Application 17488296 exit signals: Killed
Application 17488296 resources: utime ~0s, stime ~5s, Rss ~7216, inblocks ~44814, outblocks ~121023
DONE
while the output file produced is simply a reminder of my input file I used for it:
| PMEMD implementation of SANDER, Release 12
| Run on 09/12/2015 at 21:41:19
[-O]verwriting output
File Assignments:
| MDIN: LAMPLP_MD2.in
| MDOUT: LAMPLP_MD1.out
| INPCRD: LAMPLP_heat2fs.rst
| PARM: LAMPLP.prmtop
| RESTRT: LAMPLP_MD1.rst
| REFC: LAMPLP.inpcrd
| MDVEL: mdvel
| MDEN: mden
| MDCRD: LAMPLP_MD1.mdcrd
| MDINFO: mdinfo
|LOGFILE: logfile
Here is the input file:
1ns MD with distance restraints on Fe4S4 - CYS
&cntrl
imin = 0, irest = 1, ntx = 7,
ntb = 2, pres0 = 1.0, ntp = 1,
taup = 2.0,
cut = 10.0, ntr = 1,
ntc = 2,
ntf = 2,
tempi = 300.0, temp0 = 300.0,
ntt = 3, ig = -1, gamma_ln = 1.0,
nstlim = 500000, dt = 0.002,
ioutfm=1, iwrap=1,
ntpr = 500, ntwx = 500, ntwr = 1000
restraint_mask = ':1639, 1642, 1645, 1648',
restraint_wt = 1.0
vlimit = 2.0, nmropt = 1
/
&wt type = 'END' /
Does anybody know what does exactly mean?!
Many thanks,
Damiano
This message and any attachment are intended solely for the addressee
and may contain confidential information. If you have received this
message in error, please send it back to me, and immediately delete it.
Please do not use, copy or disclose the information contained in this
message or in any attachment. Any views or opinions expressed by the
author of this email do not necessarily reflect the views of the
University of Nottingham.
This message has been checked for viruses but the contents of an
attachment may still contain software viruses which could damage your
computer system, you are advised to perform your own checks. Email
communications with the University of Nottingham may be monitored as
permitted by UK legislation.
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat Sep 12 2015 - 14:00:03 PDT