Re: [AMBER] Query about microsecond long simulation

From: anu chandra <anu80125.gmail.com>
Date: Wed, 29 Apr 2015 16:46:01 +0100

Many thanks Jason and Prof. Case. A quick query here is about the value of
'gamma_In'. Is it safe to set a value of 5 ps^-1 for gamma_In? Is it going
to effect the computational time?


Thanks and regards,
Anu

On Wed, Apr 29, 2015 at 4:31 PM, David A Case <case.biomaps.rutgers.edu>
wrote:

> On Wed, Apr 29, 2015, Jason Swails wrote:
> >
> > Note that some people use the Berendsen thermostat with a long coupling
> > constant (e.g., tautp=10) as a way of doing a sort of "corrected" NVE
> > simulation in which the velocity scaling is small enough to (hopefully)
> > minimally impact the simulation while at the same time correcting for
> > potential integration errors by bleeding the extra energy introduced by
> > that (or adding energy lost by that).
>
> Just a note to be careful here. The "floating ice cube" symptom can
> reappear
> when you run long enough with ntt=1. (Previous "cures" for this, that
> involve
> stricter tolerances on Ewald and shake, may no longer work when one is
> approaching 10^9 time steps.)
>
> ....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Apr 29 2015 - 09:00:04 PDT