Re: [AMBER] Pressure units in 1D-RISM

From: David A Case <case.biomaps.rutgers.edu>
Date: Tue, 31 Mar 2015 12:09:08 -0400

On Tue, Mar 31, 2015, Maksim MiĻin wrote:
>
> I believe there is a mistake in the units of bulk solvent pressure and
> compressibility reported by the latest version of rism1d program.

Our interpretation is that results in older code (AmberTools13 are earlier)
are incorrect, and that the new results (from AmberTools14) are correct.

Here is the log file from 30 May 2013:

commit 3244a10e1656b2992c19170c63802121fb54b993
Author: Tyler Luchko <tluchko.rutgers.edu>
Date: Thu May 30 16:55:45 2013 -0400

    rism1d: corrected pressure and compressibility units in output
    was incorrectly reporting MPa instead kPa.

...hope this helps....dac


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Mar 31 2015 - 09:30:03 PDT