Re: [AMBER] PBSA in AT14: invalid test case, estatic potential values are written in wrong units to DX files.

From: Ray Luo, Ph.D. <ray.luo.uci.edu>
Date: Tue, 9 Sep 2014 12:28:16 -0700

Really, I'll take a look of update.5 and the output files again …

Ray
--
Ray Luo, Ph.D.
Professor,
Biochemistry, Molecular Biophysics, Chemical Physics,
Chemical and Biomedical Engineering
University of California, Irvine, CA 92697-3900
On Tue, Sep 9, 2014 at 3:28 AM, Jan-Philip Gehrcke
<jgehrcke.googlemail.com> wrote:
> Hey Ray,
>
> Thanks for the quick response! I do not understand how you have released
> or will release that update. As described, AT14 update.5 missed to fix
> named issue. Are you saying that you want to release an update for
> update.5? The version of
> http://ambermd.org/bugfixes/AmberTools/14.0/update.5 that I retrieve
> right now does not address the problem.
>
> Cheers!
>
> On 09/09/2014 12:22 AM, Ray Luo, Ph.D. wrote:
>> Hi Jan-Philip,
>>
>> Thanks a lot again for reporting! This is fixed in update.5. And the
>> master branch is finally corrected and this won't happen again. Let me
>> know if there is still problem after applying the updates.
>>
>> All the best,
>> Ray
>> --
>> Ray Luo, Ph.D.
>> Professor,
>> Biochemistry, Molecular Biophysics, Chemical Physics,
>> Chemical and Biomedical Engineering
>> University of California, Irvine, CA 92697-3900
>>
>>
>> On Mon, Sep 8, 2014 at 6:57 AM, Jan-Philip Gehrcke
>> <jgehrcke.googlemail.com> wrote:
>>> Hello!
>>>
>>> There is this daunting problem in PBSA affecting me since three releases
>>> (AT12, 13, 14). Let's fix this, once and for all, please :).
>>>
>>> Short story, what needs to be done:
>>>
>>> 1) In AmberTools/src/pbsa/pb_force.F90, line 1438, change
>>>
>>>       call gen_dx_file(xm,ym,zm,h,gox,goy,goz,phi(1:xmymzm),&
>>>
>>> to
>>>
>>>       call gen_dx_file(xm,ym,zm,h,gox,goy,goz,frcfac*phi(1:xmymzm),&
>>>
>>> 2) Adjust test case AmberTools/test/pbsa_phiout.
>>>
>>>
>>> Long story:
>>>
>>> More than two years ago, I reported that electrostatic potential values
>>> are written to a DX file by PBSA in wrong units ("internal units"
>>> instead of kcal/(mol*e): http://archive.ambermd.org/201207/0466.html
>>>
>>> This was then fixed in AT12
>>> (http://ambermd.org/bugfixes/AmberTools/12.0/bugfix.17). The problem was
>>> re-introduced in AT13, and I reported again:
>>> http://archive.ambermd.org/201311/0380.html
>>>
>>> A fix for AT13 has unfortunately never been released (according to
>>> http://ambermd.org/bugfixesat.html).
>>>
>>> My hope now was on AT 14. A fix for AT14 is documented with "update.5:
>>> Fix a number of small bugs in PBSA" ... and "Potential printing was in
>>> the internal unit."
>>>
>>> Now that I compiled it and tried it out, I realized that PBSA is still
>>> behaving erroneously. The facts:
>>>
>>> - A test case was added, but someone did not properly check the numbers,
>>> and included a test case with the invalid values being the "golden
>>> standard".
>>> - The changelog of AT14 update.5 is out-of-sync with the actual code
>>> changes.
>>>
>>> How to verify that there is a problem:
>>>
>>> 1) Go to directory amber14/AmberTools/test/pbsa_phiout.
>>>
>>> 2) View file pbsa_phi.phi.save. The absolute value of most of the
>>> numbers is below 1. Particularly large absolute values are on the order
>>> of 10.
>>>
>>> 3) View pbsa_phi.dx.save. The absolute value of most of the numbers is
>>> on the order of 100. Particularly large absolute values are on the order
>>> of 1000.
>>>
>>> These are just two different file formats that should show the same
>>> numeric values. Actually, I have found this by investigating the system
>>> of which I know that electrostatic potential values of about 10
>>> kcal/(mol*e) are realistic, but the DX file just contains too large
>>> numbers. And indeed, the pb_force.F90 part of
>>> http://ambermd.org/bugfixes/AmberTools/12.0/bugfix.17 is just not
>>> applied in AT14. so it makes sense that we are back to old (erroneous)
>>> behavior.
>>>
>>>
>>> Hoping for a PBSA that is working out-of-the-box for my purposes.. :)
>>>
>>> Cheers!
>>>
>>> Jan-Philip
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>>
>>> _______________________________________________
>>> AMBER mailing list
>>> AMBER.ambermd.org
>>> http://lists.ambermd.org/mailman/listinfo/amber
>>
>> _______________________________________________
>> AMBER mailing list
>> AMBER.ambermd.org
>> http://lists.ambermd.org/mailman/listinfo/amber
>>
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Sep 09 2014 - 12:30:03 PDT