Hi ,
I am trying to perform a QM/MM reaction and would like to sampling along a
reaction coordinate using umbrella sampling.
My reaction is a SN2 attack where atom 10, an oxygen of hydroxide, is
attack a carbon atom number 12, which is bound to a leaving group with atom
14 another oxygen.
I have set the system up like this:
variable
type=LCOD
i = (10,12,14)
r = (1.0,-1.0)
anchor_position = 3.0
anchor_strength = 10.0
end variable
I do not understand where I would defined maximum distance for my reaction
also it is not clear to me how you specify the intervals being sampling
along the reaction coordinate e.g. I would like to sample with a step size
of 0.2 Å for this reaction coordinate but after 6 Å I do not want to apply
any force for the reaction coordinate. I am using amber12 - thanks for any
suggestions.
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sun Jun 01 2014 - 18:30:02 PDT