[AMBER] Error in setting irest=1

From: Valentina Romano <valentina.romano.unibas.ch>
Date: Tue, 20 May 2014 16:14:07 +0000

Dear users

I ran a min. step for 2500 steps.
Since the energy was not stable and the RMS still high i decided to run a second min. (2500 additional steps) using as starting point the files i got from the previous step.

In the first step:
-r PknGAde-min.rst and -ref PknGAde-solv-min.rst

The 2nd step input file was the following:

Initial XMIN minimisation of PknG-Adenine complex: complex, water and ions
 &cntrl
  imin=1,
  maxcyc=2500,
  ntmin=3,
  irest=1,
  ntx=5,
  ntb=1,
  igb=0,
  ntr=0,
  cut=10,
  ntpr=10, ntwx=10, ntwr=1000

And i ran sander as follow:
 sander -O -i PknGAde-min.in -o PknGAde-min.out -p ../PknGAde_params/PknGHAdeH_ion_wt.prmtop -c PknGAde-min.rst -r PknGAde-min.rst -ref PknGAde-solv-min.rst -x PknGAde-min.mdcrd &

Thus I used as coord. the file I got from the previuos min.

I got the following error:
ERROR: I could not find enough velocities in
PknGAde-min.rst

I do not understand why i got that error.
Anyone can help me in understanding what happened?

Thank you
Valentina


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Valentina Romano | PhD Student | Biozentrum, University of Basel & SIB Swiss Institute of Bioinformatics
Klingelbergstrasse 61 | CH-4056 Basel |

Phone: +41 61 267 15 80



_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue May 20 2014 - 09:30:03 PDT