[AMBER] error in equilibration

From: Lara rajam <lara.4884.gmail.com>
Date: Wed, 7 May 2014 10:03:23 -0400

Dear Amber

I am doing a protein ligand complex simulation

I am trying it to do in NPT ensemble. I restrained and did the constant
temperature equilibration.
I kept the restrain force constant as 100 for the solute molecule .

when I did the same for the constant pressure in the second step the
equilibration is stopped in the middle by saying the error

 vlimit exceeded for step 79248; vmax = 29.6169
vlimit exceeded for step 79254; vmax = 539.7187

     Coordinate resetting (SHAKE) cannot be accomplished,
     deviation is too large
     NITER, NIT, LL, I and J are : 0 0 864 1810 1811

     Note: This is usually a symptom of some deeper
     problem with the energetics of the system.

I have read in the discussions that one way is to reduce the force constant
so i reduced it to
50 , the equilibration is going on till the specified picoseconds.

I would like to know is there any thing else I should take care , what does
the error really mean
How can I fix that for the same force constant , I can understand the
problem is with the 864 , 1810 1811 atoms am i right

how to fix this issue or decreasing the force constant and continuing the
simulation is acceptable.


thank you
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber