Re: [AMBER] vlimit exceeded error when switch from NPT to NVE

From: Quynh Vo <ziczac_nq.yahoo.com>
Date: Sun, 4 May 2014 11:06:42 -0700 (PDT)

>  NSTEP =   107800   TIME(PS) =   10607.800  TEMP(K) = 43292.26  PRESS =289914.1


> Since the program is printing out the pressure, my guess is that this may not
> be an NVE simulation(?).  Do you somehow have ntp=1 but no thermostat?  If so,
> that is your problem...for constant energy simulations you must set ntp=0.

Hi, thank you for your reply. I will test the beginning of the run and report it here. Regarding the input file, I set ntp=1 and taup=9999999 so that I can monitor the pressure as you suggested in another post.
Here is the input. Please let me know if it looks OK

  imin = 0, ntx = 5, irest  = 1, iwrap = 1, ig = -1, tol = 0.0000001,
  ntb = 2, cut = 15, ntc = 2,
  ntt = 0, ntf = 2, tempi = 298.15, temp0 = 298.15,
  ntp = 1, pres0 = 1.0, tautp = 2.00, taup = 99999999999,
  nstlim = 1000000, nscm = -1,  dt = 0.0010, nsnb = 50,
  ntpr = 200, ntwx = 5000, ntwr = 5000,
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sun May 04 2014 - 11:30:04 PDT