Re: [AMBER] Print Pressure value by using PMEMD

From: Daniel Roe <daniel.r.roe.gmail.com>
Date: Tue, 18 Feb 2014 22:53:41 -0700

Hi,

I think the issue might be here:


On Tue, Feb 18, 2014 at 10:42 PM, kurisaki <
kurisaki.ncube.human.nagoya-u.ac.jp> wrote:

> T = 0.0000, DT = 0.00000,
>
>

Since you've specified you want to restart (irest = 1) the code is trying
to take at least 1 MD step. Set dt to something like 0.001.

-Dan

-- 
-------------------------