Re: [AMBER] parmed.py setBond

From: Jason Swails <jason.swails.gmail.com>
Date: Tue, 03 Dec 2013 14:22:48 -0500

On Tue, 2013-12-03 at 14:04 -0500, Jason Swails wrote:
> On Tue, 2013-12-03 at 18:25 +0000, Aronica, Pietro wrote:
> > A premise: I'm working with an experimental protocol that requires a lot of custom residue and atom types and precise manipulation of the prmtop files. It has been described as "a prmtop-based FEP scheme" by Jason himself, and that's not far from the truth. Because of the settings of my system, it is crucial that the exclusion list is kept the way I originally make it in order to avoid instabilities and failures. Indeed, I manually edited the prmtop files to change only the bond length I needed to modify (which is what I expected parmed.py to do) and the issue disappeared.
> > The command is as follows:
> >
> > setBond :MKN.CH :MKA.CG 340 1.526
> > setOverwrite
> > parmout Solv_100_0.prmtop
> >
> > There's a few more, varying from 10_90 to 100_0, with different values for the equilibrium distance and the force constant. In each case, the bond parameters are correctly modified, but in addition the number of excluded atoms goes from 28762 to 28755. I'm wading through the exclusion list to pinpoint the change, but it arises from the custom residue where the bond is modified. That is the only instance of the bond in the system.
> > I figure it's probably my delicate prmtop manipulations that are causing this, but I don't understand why the setBond command should touch the exclusion list at all if the bond is already there and connectivity is unchanged.

I think I may have misinterpreted this part of your email the first time
around. Does the above ("delicate prmtop manipulations") mean that you
have already used "addExclusions" in a previous ParmEd session to add
exclusions to your original topology file? If so, then any "topology
recalculation" will destroy those previously-defined exclusions. (The
exclusion list is not processed when it is read from the prmtop, it is
merely recreated when the topology changes). The changes made by
"addExclusions" will persist for the entire ParmEd session, but not for
any future ones.

I hadn't thought about this issue before. A few things to note here:
sander and pmemd ignore the exclusion list stored in the topology file
for PME (explicit solvent) calculations---they simply regenerate the
exclusion list from the bonds, angles, and torsions. The GB
calculations in sander and pmemd _do_ obey the exclusion list stored in
the prmtop.

> If you send me your prmtop file and your inpcrd file I will try to take
> a look.

If you do send me the files, please send it privately. I forgot to
mention that.

-- 
Jason M. Swails
BioMaPS,
Rutgers University
Postdoctoral Researcher
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Dec 03 2013 - 11:30:04 PST