Re: [AMBER] Question: MM/PBSA and MM/GBSA

From: Hiromasa WATANABE <hi-watanabe.hpc.co.jp>
Date: Fri, 13 Sep 2013 11:06:36 +0900

Dear Dr. Ray,

To do same calculation as the paper J. Phys. Chem. B 117, 8408 (2013),
in my thoughts, its values seems to be different from the default ones of MM_PBSA program.

Here's a summary of information of the paper:

In both MM/GBSA and MM/PBSA:
* SASA based on LCPO algorithm is used for nonpolar desolvation free energy (dG_SA).
     dG_SA = 0.0072 x dSASA

* Interior dielectric constant (solute) is 1, 2 or 4.
   Exterior dielectric constant (solvent) is 80.

In MM/GBSA:
* Onufrievs' modified GB is used for polar desolvation free energy (dG_GB).

In MM/PBSA:
* Tan & Luo radii is used for polar desolvation free energy (dG_PB).


Therefore, I set,
   INDI=1.0, EXDI=80.0 in both MM/GBSA and MM/PBSA.
   IGB=2 in MM/GBSA.
   RADIOPT=1, INP=2 in MM/PBSA.


Q1.
According to the explanation of "MS" in AMBER manual,
to use LCPO, MS=0 and GB=1 for MM/GBSA,
but I don't know that for MM/PBSA.
Does MS=0 and PB=1 work fine?

Q2.
In the above paper, dG_SA = 0.0072 x dSASA.
So, according to the explanation of "INP" in AMBER manual,
should I set SURFTEN=0.0072, SURFOFF=0.0 in both MM/GBSA and MM/PBSA ?

Q3.
Do I need any other settings?


Best regards,
WATANABE


> Dear Dr. Ray,
>
> Thank you very much for your rapid reply.
>
> To use Tan & Luo radii, by setting radiopt=1 and inp=2,
> appropriate values are set to the others automatically, aren't they?
> I'll try.
>
> Thanks,
> WATANABE
>
>> WATANABE,
>>
>> For PB, please only set radiopt=1 and inp=2. If you don't feel
>> comfortable with setting the many options, don't set other options
>> such as ARCRES, SURFTEN, SURFOFF since the default values has been set
>> to be compatible in the program.
>>
>> Also, the python script is somewhat more robust in setting options if
>> you really want to try these options out ...
>>
>> Ray
>>
>> On Wed, Sep 11, 2013 at 1:56 AM, Hiromasa WATANABE
>> <hi-watanabe.hpc.co.jp> wrote:
>>> Dear Amber supporters,
>>>
>>> I'm trying MM/PBSA calculation and MM/GBSA calculation using AMBER12's MM_PBSA.
>>> In order to perform same calculation as Lei Xu et al., J. Phys. Chem. B 117, 8408 (2013),
>>> I've created input file like below.
>>> Would you please check if parameter values and consistency are OK?
>>>
>>> (1)
>>> In MM/PBSA calculation, to use Tan & Luo radii,
>>> according to the AMBER manual(p.329),
>>> values of SURFTEN and SURFOFF are set like below, is this OK?
>>>
>>> .GENERAL
>>> MM 1
>>> GB 0
>>> PB 1
>>> MS 1
>>>
>>> .MM
>>> DIELC 1.0
>>>
>>> .PB
>>> PROC 2
>>> REFE 0
>>> INDI 1.0
>>> EXDI 80.0
>>> SCALE 2
>>> LINIT 1000
>>> ISTRNG 0.0
>>> RADIOPT 1
>>> ARCRES 0.0625
>>> INP 2
>>>
>>> SURFTEN 0.005
>>> SURFOFF 0.86
>>>
>>> IVCAP 0
>>> CUTCAP -1.0
>>> XCAP 0.0
>>> YCAP 0.0
>>> ZCAP 0.0
>>>
>>> .MS
>>> PROBE 0.0
>>>
>>> (2)
>>> In MM/GBSA calculation, to use Onufriev's GB and LCPO method,
>>> following settings are OK?
>>>
>>> .GENERAL
>>> MM 1
>>> GB 1
>>> PB 0
>>> MS 1
>>>
>>> .MM
>>> DIELC 1.0
>>>
>>> .GB
>>> IGB 2
>>> GBSA 1
>>> SALTCON 0.00
>>> EXTDIEL 80.0
>>> INTDIEL 1.0
>>>
>>> SURFTEN 0.005
>>> SURFOFF 0.00
>>>
>>> .MS
>>> PROBE 0.0
>>>
>>>
>>> Best regards,
>>> WATANABE
>>>
>>> --
>>> Hiromasa WATANABE
>>> Manager, Ph.D.
>>> HPC Dept., Technology Gr., HPC SYSTEMS Inc.
>>> Head office: LOOP-X 8F, 3-9-15 Wangan, Minato-ku, Tokyo, Japan 108-0022.
>>> Email: hi-watanabe.hpc.co.jp
>>> www.hpc.co.jp
>>>
>>> _______________________________________________
>>> AMBER mailing list
>>> AMBER.ambermd.org
>>> http://lists.ambermd.org/mailman/listinfo/amber
>>
>> _______________________________________________
>> AMBER mailing list
>> AMBER.ambermd.org
>> http://lists.ambermd.org/mailman/listinfo/amber
>>
>> __________ Information from ESET NOD32 Antivirus, version of virus signature database 8789 (20130911)
>> __________
>>
>> The message was checked by ESET NOD32 Antivirus.
>>
>> http://www.eset.com
>>
>>
>>
>>
>

-- 
HPCシステムズ株式会社 ( http://www.hpc.co.jp/ )
HPC事業部 技術グループ 渡邊 啓正 <hi-watanabe.hpc.co.jp>
〒108-0022 東京都港区海岸3-9-15 LOOP-X 8階
TEL:03-5446-5530(代表)/FAX:03-5446-5550(共通)
Hiromasa WATANABE
Manager, Ph.D.
HPC Dept., Technology Gr., HPC SYSTEMS Inc.
Head office: LOOP-X 8F, 3-9-15 Wangan, Minato-ku, Tokyo, Japan 108-0022.
Email: hi-watanabe.hpc.co.jp
www.hpc.co.jp
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Sep 12 2013 - 19:30:02 PDT