Alberto,
I tested Gaussian03. Punch=Derivatives does not work as described in the manual. As such this is a bug in my AMBER module since it should get the forces from the Gaussian03 output file instead. The fort.7 file you see is created by AMBER when it tries to open the file for reading. This will require a bugfix. My apologies.
All the best,
Andy
--
Dr. Andreas W. Goetz
Assistant Project Scientist
San Diego Supercomputer Center
Tel : +1-858-822-4771
Email: agoetz.sdsc.edu
Web : www.awgoetz.de
On Jul 25, 2013, at 10:41 AM, Alfredo Quevedo wrote:
> Dear Andreas, thank you very much for your feedback. As you point out I
> was expecting that the keyword "Punch=Derivatives" in the route section
> of gaussian may wirte the information required by sander to continue
> with the QM/MM calculation. The problem is that the file 'fort.7' is
> created by gaussian03 but it is empty although the gaussian job end
> without problem. To test this I used the example provided with Amber12
> under the test directory.
>
> The input to sander for the QM/MM simulation is:
>
> Geometry optimization with Gaussian, 2 steps steepest descent
> &cntrl
> imin=1, ! do a minimization
> maxcyc=2, ! max 2 minimization steps
> ncyc=2 , ! switch to conjugate gradient after 2 steps of steepest
> descent
> drms=0.5, ! RMS gradient convergence criterium 0.5 (kcal/mol)/A =
> 2.d-3 au
> cut=9999.0, ! non-bonded cutoff (irrelevant for now with pure QM)
> ntb=0, ! no periodic boundary conditions
> ntpr=1, ! print every minimization step
> ntwx=1, ! write coordinates each step
> ntwr=2, ! write restart file at last step
> ioutfm = 1, ! NetCDF MDCRD.
> ifqnt=1 ! do QM/MM
> /
> &qmmm
> qmmask ='.*',
> qmcharge = 0,
> qm_theory ='EXTERN',
> verbosity = 0,
> /
> &gau
> basis = 'STO-3G',
> method = 'BLYP',
> charge = 0,
> /
>
>
> The input to Gaussian03 as created by sander is:
>
> %chk=gau_job.chk
> %NProcShared=1
> #P BLYP/STO-3G SCF=(Conver=8) Force Punch=Derivatives NoSymm
>
> Gaussian run using SANDER external interface.
>
> 0 1
> O 0.0000000000000000 0.0000000000000000 0.0000000000000000
> H 1.5000000000000000 0.0000000000000000 0.0000000000000000
> H 0.0000000000000000 1.5000000000000000 0.0000000000000000
>
>
> The .inpcrd and .prmtop files I used are 'h2o.inpcrd' and 'h2o.prmtop',
> respectively, under $AMBERHOME//test/qmmm_EXTERN/pure_QM_MD_GAUSSIAN
>
> As can be seen, the 'Punch=Derivative' keyword is present, and although
> the Gaussian calculation ends up OK, charges are not dumped to fort.7.
>
> Which may be causing this situation?
>
> Thank you very much in advance,
>
> Kind regards
>
> Alfredo
>
>
>
> El 24/07/2013 17:58, Andreas Goetz escribió:
>> Hi Alfredo,
>>
>> According to the Gaussian03 manual, the file fort.7 should be written if the input file contains "Punch=Derivatives" in the route section (which is the case for input generated by the QM/MM interface in sander). I am almost sure this was tested at some point but do not have access to Gaussian03 to verify.
>>
>> All the best,
>> Andy
>>
>> --
>> Dr. Andreas W. Goetz
>> Assistant Project Scientist
>> San Diego Supercomputer Center
>> Tel : +1-858-822-4771
>> Email: agoetz.sdsc.edu
>> Web : www.awgoetz.de
>>
>> On Jul 24, 2013, at 8:07 AM, Alfredo Quevedo wrote:
>>
>>> Good morning: I am trying to run a test QM/MM simulation using
>>> Gaussian03 as external software. The simulation does not finishes
>>> because the file fort.7 is not being created. Searching in the amber
>>> archive I found the following related thread:
>>>
>>> http://archive.ambermd.org/201205/0437.html
>>>
>>> in which the same problem was reported. The reported solution was to use
>>> Gaussian09 instead of Gaussian03.
>>> My question is: has anyone succeded in running QM/MM simulations using
>>> Gaussian03?. In that case, how may the problem related to fort.7 file
>>> be fixed?
>>>
>>> Thank you very much in advance for the help,
>>>
>>> kind regards
>>>
>>> Alfredo
>>>
>>> --
>>> *********************************************************
>>> Prof. Dr. Mario Alfredo Quevedo.-
>>> Laboratorio de Química Medicinal.-
>>> Dpto. de Farmacia - Fac. de Ciencias Químicas.-
>>> Universidad Nacional Córdoba.-
>>> 5000 Córdoba, Argentina
>>> TE: +54 351 5353865 Int: 53355
>>>
>>>
>>> _______________________________________________
>>> AMBER mailing list
>>> AMBER.ambermd.org
>>> http://lists.ambermd.org/mailman/listinfo/amber
>>
>> _______________________________________________
>> AMBER mailing list
>> AMBER.ambermd.org
>> http://lists.ambermd.org/mailman/listinfo/amber
>
>
> --
> *********************************************************
> Prof. Dr. Mario Alfredo Quevedo.-
> Laboratorio de Química Medicinal.-
> Dpto. de Farmacia - Fac. de Ciencias Químicas.-
> Universidad Nacional Córdoba.-
> 5000 Córdoba, Argentina
> TE: +54 351 5353865 Int: 53355
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Jul 25 2013 - 16:30:02 PDT