Re: [AMBER] Seg Fault in antechamber while writing ANTECHAMBER_AM1BCC_PRE.AC

From: FyD <fyd.q4md-forcefieldtools.org>
Date: Sat, 25 May 2013 18:00:09 +0200

Dear Jacob,

> Thank you both very much for your suggestions. Francois, looking at the
> links you provided, I will certainly investigate different ways of
> parameterizing the molecule in representative units. I was hesitant to do
> this at first since the molecule contains an extended network of aromatic
> rings linked by oxygen atoms, but agree that it is certainly worth looking
> into.

splitting a conjugated system into different building blocks is more tricky...
difficult to help without a picture of your molecule...

regards, Francois


> On Fri, May 24, 2013 at 8:11 AM, David A Case
> <case.biomaps.rutgers.edu>wrote:
>
>> On Thu, May 23, 2013, Jacob Monroe wrote:
>> >
>> > When I run antechamber for a specific molecule, it throws a seg fault
>> after
>> > sqm finishes. The molecule is large at 184 atoms, and has a -8 charge,
>> but
>> > this should not be an issue once calculations are completed. A similar
>> > problem was mentioned in the
>> > archive<http://archive.ambermd.org/201101/0383.html>,
>>
>> Note that in the archive article you mention, I could not reproduce the
>> problem. This suggests that we need information about which version you
>> are
>> using, and which OS and compiler are involved.
>>
>> If you wish, you can post the sqm.in file, and I'll try to run it here. It
>> could be that this time the error will be reproducible. If not, you'll
>> have
>> to compile sqm with debug options and run it under the debugger to try to
>> find
>> the source of the error.



_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat May 25 2013 - 09:30:03 PDT