Re: [AMBER] GAFFlipid FF concern

From: Dickson, Callum <callum.dickson09.imperial.ac.uk>
Date: Wed, 9 Jan 2013 14:08:24 +0000

Hi,

We have recently been made aware of this error (it was a typo unfortunately). Correcting the hydrogen mass somewhat drops the area per lipid further from experiment.

We are currently working on an update to rectify this error now.

Callum
________________________________________
From: amber-bounces.ambermd.org [amber-bounces.ambermd.org] on behalf of jfloresc.andrew.cmu.edu [jfloresc.andrew.cmu.edu]
Sent: 08 January 2013 21:54
To: amber.ambermd.org
Subject: [AMBER] GAFFlipid FF concern

Hello All,

I have found what I believe it is a typo on GAFFlipid.frcmod, please
correct if I am wrong. The mass of hydrogen atom type 'hl' is typed as
1.088 an it is claimed to be equal to GAFF atom type 'hc', which has mass
1.008.

I wonder if this issue has any significant effect on reported simulations
and conclusions of [Dickson, C.J., et al. Soft Matter (2012)]. So far,
this typo is repeated in DOPC, DPPC and POPC zip files.

Best,
Jose