Re: [AMBER] Is AM1-BCC charges ok for ligands with idodine atoms

From: FyD <fyd.q4md-forcefieldtools.org>
Date: Wed, 09 Jan 2013 09:56:50 +0100

Dear Shulin Zhuang,

You might be interested in deriving RESP charges using R.E.D.
without/without R.E.D. Server... R.E.D. Server Development
automatically handles iodine (you need to provide the radius for MEP
computation for iodine).
See http://q4md-forcefieldtools.org/REDS-Development/popup/popkeyword.php

regards, Francois


> I performed one MD simulation on triiodothyronine (T3) and its target
> protein. This molecule has three iodine atoms and I use sqm from
> ambertools 1.5 to assign AM1-BCC charge for T3. One reviewer thought that
> AMB-BCC charge is known to be quite inaccurate. This is one of key
> technical questions for the rejection of my publication.
>
>
> After MD simulations, I performed RAMD simulations and RAMD simulations
> revealed some dissociation pathways, some of them were verified by previous
> relevant papers. I think the parameters no problem. The reviewer kindly
> asked me yo provide some quantitative indications that the parameters
> obtained yield reliable or reasonable behavior for the T3 molecule. Could
> anybody tell me how to prove that AM1-BCC charge is reasonable for T3?