[AMBER] Fatal error (Could not read velocities) during heating

From: Zalikha Ibrahim <zalikha.ibrahim.yahoo.com>
Date: Wed, 15 Aug 2012 02:09:51 -0700 (PDT)

Dear all Amber user,

I have previously minimized the system that I currently work on and now I am trying to perform heating. The parameters are as below: 

MD simulation heating the protein
 &cntrl
   imin=0, irest=1, ntx=5,
   ntf=2, ntc=2, tol=0.0000001, ntb=2, igb=0,
   ntt=3, temp0=300.0, gamma_ln=1.0
   ntp=1, pres0=1.0, taup=1,
   nstlim=20000, dt=0.002,
   cut=8.0
   ntpr=50, ntwr=500, ntwx=500, iwrap=1,
  /


It stopped with this message --> FATAL: Could not read velocities from prot_min.rst

I would be very grateful if anyone could tell me what does this mean and how to make it work. Plus, any suggestion on how to check whether our output (.rst) is correct.

Thanks 

Zalikha
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Aug 15 2012 - 02:30:03 PDT