On Tue, Aug 7, 2012 at 9:53 AM, Vlad Cojocaru <
vlad.cojocaru.mpi-muenster.mpg.de> wrote:
> Jason,
>
> However, one mistery remains. Why using inp=2 and radiopt=0 still gives
> the same error but inp=1 and radiopt=0 does not ? As far as I got it,
> radiopt=0 should force to read radii from the topology file and
> therefore in should work with any inp value. Or maybe when setting inp=2
> the program overwrites automatically the radiopt=0 from the input file ?
>
It seems that your latter guess is right. From the PBSA source code:
if ( inp == 2 .and. radiopt /= 1 ) then
write(6, *) 'PB Warning in pb_read(): radiopt has been reset to 1
because inp=2.'
radiopt = 1
end if
Do you see that warning in the output file? In the long run, I think
modifying the source code to recognize ILDN atom types is the best
solution, but the xparmed.py fix I mentioned previously is a good
workaround for the time being.
HTH,
Jason
--
Jason M. Swails
Quantum Theory Project,
University of Florida
Ph.D. Candidate
352-392-4032
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber