Dear Amber users, I would like to pose you the following question.
I am simulating a charged system (a bulk liquid ionic made up of
cations and anions, but the same problem should apply, in principal,
to any ion-molecule system).
>From a series of ab initio calculation, I obtain that a great amount
of charge transfer takes place between cation and anion (I calculated
the point charges with various methods, such as RESP/HF and CHELPg/MP2
or others, on small models like ionic couple, tetramer and hexamer).
To account for this phenomenon in the classical simulation, without
using a polarizable force field, I am trying to rescale the ab initio
charges (calculated in vacuo for the free ion) by a given percentage
(for instance, 0.9, 0.8 and 0.7). I thought that the same effect could
be obtained by using a dielectric constant in the simulation, e. g.
eps=1.5625 if I scale by 0.8; 1/(0.8*0.8)=1.5625.
But the results I obtain with direct charge scaling and with the
modified dielectric constant are rather different. Am I making a great
mistake, or does the dielectric constant play a role that I don't see
(for instance, in Ewald sums?)
Thanks for any suggestion
Lorenzo
--
==========================================
Lorenzo Gontrani
Research associate of CNR-ISTM (Rome Tor Vergata)
EDXD group of University of Rome "La Sapienza"
GSM +39 338 7615798
Email l DOT gontrani AT caspur DOT it
Webpage: http://webcaminiti/gontrani.html
=========================================
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Apr 18 2012 - 04:00:03 PDT