thank you very much for reply.
problem solved with the latest Schrodinger2012 suite.....
best
Albert
On 04/16/2012 09:30 PM, David A Case wrote:
> On Mon, Apr 16, 2012, Albert wrote:
>
>> I am following the guide at : http://ambermd.org/desmond.html and
>> trying to convert an Amber MD system into Desmond system. It do
>> generated a .cms file, but what I found is that all the residues are
>> renamed 'UNK' and we cannot differentiate which one is which one when I
>> import to VMD or Maestro..
> You should probably take these questions to the Schrodinger people, since they
> are the ones who have written these codes. My experience is that they are
> generally quite helpful.
>
> The "UNK" behavior is what we see as well.
>
>
> .. Moreover, I try to run 'build constrain steps', there are some problems:
>> ValueError: No angle found for atoms 4684 4683 4685
> All I can say here is that, according to what I have been told(!?!), this step
> is not needed. I'm guessing that atoms 4683 to 4685 form a water molecule,
> and Amber typically does not keep the force constants for those. Given LEaP
> the command "set default flexible water on" before making the Amber prmtop
> may help.
>
> ....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Apr 16 2012 - 14:30:02 PDT