Re: [AMBER] closest command

From: Qiong Zhang <qiong.zhang.qzh.gmail.com>
Date: Fri, 13 Apr 2012 08:51:24 -0400

Hi Dan,

Thank you for your attention.

I've patched all the bugfixes for AT1.5. I checked the cpptraj tests. They
all passed including the Test_Closest.

This time I fed in a short trajectory with only 5 frames. Now I got all the
outputs.

parm comp-696w.top
trajin comp-696w.mdcrd 1 5 1
closest 10 :1-390 first closestout closestmols.dat outprefix closest
trajout first.Closest.pdb pdb

comp-696w.mdcrd is a trajectory with 696 closest water to residue 1-390
produced by ptraj. With the above script, through cpptraj I got in the
closestmols.dat the following contents:

#Frame Mol Dist FirstAtm
            0 0 0.0000 6028
            0 1 0.0000 6031
            0 2 0.0000 6034
            0 3 0.0000 6037
            0 4 0.0000 6040
            0 5 0.0000 6043
            0 6 0.0000 6046
            0 7 0.0000 6049
            0 8 0.0000 6052
            0 9 0.0000 6055
            1 0 0.0000 6028
            1 1 0.0000 6031
            1 2 0.0000 6034
            1 3 0.0000 6037
            1 4 0.0000 6040
            1 5 0.0000 6043
            1 6 0.0000 6046
            1 7 0.0000 6049
            1 8 0.0000 6052
            1 9 0.0000 6055
            2 0 0.0000 6028
            2 1 0.0000 6031
            2 2 0.0000 6034
            2 3 0.0000 6037
            2 4 0.0000 6040
            2 5 0.0000 6043
            2 6 0.0000 6046
            2 7 0.0000 6049
            2 8 0.0000 6052
            2 9 0.0000 6055
            3 0 0.0000 6028
            3 1 0.0000 6031
            3 2 0.0000 6034
            3 3 0.0000 6037
            3 4 0.0000 6040
            3 5 0.0000 6043
            3 6 0.0000 6046
            3 7 0.0000 6049
            3 8 0.0000 6052
            3 9 0.0000 6055
            4 0 0.0000 6028
            4 1 0.0000 6031
            4 2 0.0000 6034
            4 3 0.0000 6037
            4 4 0.0000 6040
            4 5 0.0000 6043
            4 6 0.0000 6046
            4 7 0.0000 6049
            4 8 0.0000 6052
            4 9 0.0000 6055

So in the "FirstAtm" column, it is the Index of the O atoms for those
closest waters. And they are ordered according to their closeness to resid
1-390. Am I right?

But why are there all 0.0000 in the Dist column please? What should be the
exact meaning for Dist please? Shouldn't it be the distance of this O atom
to resid 1-390?

Thank you a lot !

Qiong





On Fri, Apr 13, 2012 at 7:33 AM, Daniel Roe <daniel.r.roe.gmail.com> wrote:

> Hi,
>
> It's difficult to know what exactly is going on without more
> information. Can you please provide the exact output cpptraj gives
> (stdout)? Also, do all of the AT1.5 cpptraj test cases pass, and what
> bugfixes (if any) have you applied? Thanks.
>
> -Dan
>
> On Thu, Apr 12, 2012 at 9:29 PM, Qiong Zhang <qiong.zhang.qzh.gmail.com>
> wrote:
> > Hi Dan,
> >
> > Yes, I was using ptraj. Thank you for pointing this out.
> >
> > I tried cpptraj with this input:
> >
> > trajin traj.mdcrd 1 5 1
> > trajout test.mdcrd nobox
> > center :1-10 mass origin
> > closest 20 :1-10 first closestout closestout.dat
> >
> > There was no output produced, not even test.mdcrd. With ptraj, at least
> the
> > correct test.mdcrd was produced.
> >
> > Am I missing anything for cpptraj please?
> >
> > Thanks!
> >
> > Qiong
> >
> >
> >
> > On Thu, Apr 12, 2012 at 7:02 PM, Daniel Roe <daniel.r.roe.gmail.com>
> wrote:
> >
> >> Are you using ptraj? The 'closestout' keyword is only implemented in
> >> cpptraj.
> >>
> >> -Dan
> >>
> >> On Apr 12, 2012, at 5:30 PM, Qiong Zhang <qiong.zhang.qzh.gmail.com>
> >> wrote:
> >>
> >> > Hi all,
> >> >
> >> > I am using ambertools1.5 and encountered a problem when using the
> closest
> >> > command. The script I am using is as follows:
> >> >
> >> > trajin traj.mdcrd 1 5 1
> >> > trajout test.mdcrd nobox
> >> > solvent byname WAT
> >> > center :1-10 mass origin
> >> > closest 20 :1-10 first closestout closestout.dat
> >> >
> >> > With this I can obtain the trajectory output test.mdcrd where the 20
> >> > closest waters to residue 1-10 are selected. But no *closestout.dat*
> file
> >> > was produced.
> >> > In the manual it says that " If “closestout” is specified information
> on
> >> > the closest solvent molecules will be print to
> >> > <filename> with format:
> >> > Frame Molecule Distance FirstAtom# "
> >> >
> >> > Could anybody please give me some hint on what might be wrong here
> >> please?
> >> > Thanks!
> >> >
> >> > And if the closestout.dat is produced, what exact content is in this
> file
> >> > please? Will the RESID or AtomID of the closest solvent be given as
> >> > FirstAtom# please?
> >> >
> >> > Qiong
> >> > _______________________________________________
> >> > AMBER mailing list
> >> > AMBER.ambermd.org
> >> > http://lists.ambermd.org/mailman/listinfo/amber
> >>
> >> _______________________________________________
> >> AMBER mailing list
> >> AMBER.ambermd.org
> >> http://lists.ambermd.org/mailman/listinfo/amber
> >>
> > _______________________________________________
> > AMBER mailing list
> > AMBER.ambermd.org
> > http://lists.ambermd.org/mailman/listinfo/amber
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Apr 13 2012 - 06:00:07 PDT